Description:
Ionizing blower is a special device to eliminate static electricity, widely used on SMT factory production lines. The EI-1200A is easy to install, operates smoothly, and eliminates static electricity quickly.
Operating Principle:
The Ionizing blower EI-1200A can produce a substantial airflow carrying both positive and negative charges, effectively neutralizing charges on objects. When an object surface holds a negative charge, it attracts positive charges from the airflow. Conversely, when the surface carries a positive charge, it draws negative charges from the airflow. This process helps neutralize static electricity on the object’s surface, achieving the goal of eliminating static charges.
Features:
Ionizing blower EI-1200A can provide hot air to meet application needs in different seasons. Just adjust the air volume within a wide range by the speed control switch. Please note: When turning on the hot air outlet, please adjust the air volume to the maximum limit position!
The Ionizing blower EI-1200A has 2 ionizing devices. These devices create a stable high-strength electric field by utilizing low current and high voltage from the high-voltage generator. They ionize the air, generating ions. And ions go to the object surface through the airflow to neutralize static electricity. Additionally, the ionizing device includes a specialized cleaner designed to eliminate dust buildup on the ionizing needle, ensuring the proper functioning of the device.
Besides, the EI-1200A has a dedicated ion balance circuit to achieve automatic ion balance.
The static elimination function of Ionizing blower EI-1200A addresses production issues arising from static electricity, including problems with dust absorption, adhesion in plastic processing, and small parts jumping due to static repulsion. In a word, it can quickly neutralize static electricity. Ionizing blower EI-1200A has good grounding protection. Ionizing blower EI-1200A has a large ion airflow coverage area, up to 140cm × 120cm.
Specification
Model | EI-1200A |
Operating Voltage | 110V/60Hz or 220V/50Hz |
Power | 40w to 80w |
Operating Temperature | -10-50℃ |
Air Coverage | 140cm × 120cm |
Size | 1280cm (L) × 215mm (W) × 190mm (H) |
Weight | 10.2kg |
Air Volume | 150~360CFM |
Ion Balance | 0V±10V |
Decay Test Conditions | ||||
Operating Voltage :110V/220V Testing Voltage:1KV to 100V Temperature:22℃ | ||||
Distance | 300mm | 600mm | 900mm | 120mm |
Left | 1.2s | 2.4s | 3.9s | 5.6s |
Center | 1.1s | 2.2s | 3.6s | 5.5s |
Right | 1.1s | 2.2s | 3.8s | 5.9s |
Notice: The ion balance voltage and static elimination time comply with ESD standards. The static elimination time is measured from 1000V to 100V using the ME268A electrostatic comprehensive tester. It’s important to note that the testing data may vary due to changes in temperature and humidity in the surrounding air.