Description:
Ionizing air blower is a special device to eliminate static electricity, widely used on SMT factory production lines. The EI-028 is easy to install, operates smoothly, and eliminates static electricity quickly.
Operating Principle:
The Ionizing blower EI-028 can produce a substantial airflow carrying both positive and negative charges, effectively neutralizing charges on objects. When an object surface holds a negative charge, it attracts positive charges from the airflow. Conversely, when the surface carries a positive charge, it draws negative charges from the airflow. This process helps neutralize static electricity on the object’s surface, achieving the goal of eliminating static charges.
Features:
Ionizing blower EI-028 can provide hot air to meet application needs in different seasons. Just adjust the air volume within a wide range by the speed control switch. Please note: When turning on the hot air outlet, please adjust the air volume to the maximum limit position!
The Ionizing blower EI-028 has 2 ionizing devices. These devices create a stable high-strength electric field by utilizing low current and high voltage from the high-voltage generator. They ionize the air, generating ions. And ions go to the object surface through the airflow to neutralize static electricity. Additionally, the ionizing device includes a specialized cleaner designed to eliminate dust buildup on the ionizing needle, ensuring the proper functioning of the device.
Besides, the EI-028 has a dedicated ion balance circuit to achieve automatic ion balance.
Ionizing air blower EI-028’s static elimination function can solve production problems caused by static electricity, such as solving dust absorption problems caused by static electricity, adhesion problems during plastic processing, and small parts jumping issues caused by static repulsion.
In a word, it can quickly neutralize static electricity. Ionizing air blower EI-028 has good grounding protection. Ionizing air blower EI-028 has a large ion airflow coverage area, up to 60x120cm.
Specification
Operating Voltage | 110V/60Hz or 220V/50Hz |
Current Consumption | 3.0A or1.5A |
Operating Temperature | 0-50℃ |
Air Coverage | 60cm×120cm |
Size | 450mm(L) ×220mm(W) ×190mm(H) |
Weight | 8kg |
Air Volume | 70~120CFM |
Ion Balance | 0V±10V |
Decay Test Conditions | ||||
Operating Voltage:110V/220V Testing Voltage:1KV to 100V Temperature:22℃ | ||||
Distance | 300mm | 600mm | 900mm | 1200mm |
Left 300mm(左300mm) | 1.2s | 2.4s | 3.9s | 5.6s |
Centre(中心) | 1.1s | 2.2s | 3.6s | 5.5s |
Right 300mm(右300mm) | 1.1s | 2.2s | 3.8s | 5.9s |
Notice: The ion balance voltage and static elimination time comply with ESD standards. The static elimination time is measured from 1000V to 100V using the ME268A electrostatic comprehensive tester. It’s important to note that the testing data may vary due to changes in temperature and humidity in the surrounding air.